Iranian Journal of Mechanical Engineering Transactions of ISME

Iranian Journal of Mechanical Engineering Transactions of ISME

Experimental study of dehumidification of humid air over a finned tube by free convection

Authors
Abstract
In this study, dehumidification of humid air over a horizontal annular finned-tube by free convection for various relative humidities is investigated experimentally. The finned-tube is placed in an isolated test room in order to perform pure natural convection. The test room ambient air temperature and relative humidity are controlled by air cooling and heating cycles and humidifying system. Measurements are carried out for an annular finned-tube with outer tube diameter 25.4 mm, fin thickness 0.4 mm, fin outer diameter 56.0 mm, and fin density 11 FPI (433 FPM). For experimental measurements, ambient air and fin base temperature are taken 30°C and 8°C, respectively and relative humidity is changed from 25% to 70%. All measurements are made from beginning of cooling until steady state condition approached. For each test, flow structure, heat transfer and condensation rate are discussed. It is found that condensation rate, drop coalescence, and heat transfer rate depend mainly on the relative humidity. When relative humidity increases, heat and mass transfer rate are increased.
Also, natural dehumidification shows that the drops form mainly on the tip of the fins and no condensation is observed between the fins which is mainly due to small fin spacing and no air movement between the fins.
Keywords

[1] Nusselt, W., "Die Oberflächenkondensation des Wasserdampfes", Zeitschrift des Vereines Deutscher Ingenieure, Vol. 60, pp. 541-546, (1916).
 
[2] Elmahdi, A. H., and Biggs, R. C., "Efficiency of Extended Surfaces with Simultaneous Heat and Mass Transfer", ASHREA Transactions, Vol. 89, pp. 135-143, (1983).
 
[3] Coney, J. E. R., Sheppard, C. G. W., and El-Shafei, E. A. M., "Fin Performance with Condensation from Humid Air: A Numerical Investigation", International Journal of Heat and Fluid Flow, Vol. 10, pp. 224-231, (1989).
 
[4] Coney, J. E. R., El-Shafei, E. A. M., and Sheppard, C. G. W., "Experimental Investigation of a Cooled Thick Fin in Dry and Humid Air Flows", International Journal of Refrigeration, Vol. 12, pp. 332-337, (1989).
 
[5] Wu, G., and Bong, T. Y., "Overall Efficiency of a Straight Fin with Combined Heat and Mass Transfer", ASHREA Transactions, Vol. 100, pp. 367-374, (1994).
 
[6] Kazeminejad, H., "Analysis of One-dimensional Fin Assembly Heat Transfer with Dehumidification", International Journal of Heat and Mass Transfer, Vol. 38, No. 3, pp. 455-462, (1995).
 
[7] Salah El-Din, M. M., "Performance Analysis of Partially-wet Fin Assembly", Applied Thermal Engineering, Vol. 18, pp. 337-349, (1998).
 
[8] Rosario, L., and Rahman, M. M., "Overall Efficiency of a Radial Fin Assembly under Dehumidifying Conditions", ASME Journal of Energy Resources Technology, Vol. 120, pp. 299-305, (1998).
 
[9] Rosario, L., and Rahman, M. M., "Analysis of Heat Transfer in a Partially Wet Radial Fin Assembly during Dehumidification", International Journal of Heat and Fluid Flow, Vol. 20, pp. 642-648, (1999).
 
[10] Naphon, P., "Study on the Heat Transfer Characteristics of the Annular Fin under Dry-surface, Partially Wet-surface, and Fully Wet-surface Conditions", International Communications in Heat and Mass Transfer, Vol. 33, pp. 112-121, (2006).
 
[11] Sharqawy, M. H., and Zubair, S. M., "Efficiency and Optimization of an Annular Fin with Combined Heat and Mass Transfer - An Analytical Solution", International Journal of Refrigeration, Vol. 30, pp. 751-757, (2007).
 
[12] Kundu, B., and Barman, D., "Analytical Study on Design Analysis of Annular Fins under Dehumidifying Conditions with a Polynomial Relationship between Humidity Ratio and Saturation Temperature", International Journal of Heat and Fluid Flow, Vol. 31, pp. 722-733, (2010).
 
[13]  Sharqawy, M. H., Moinuddin, A., and Zubair, S. M., "Heat and Mass Transfer from Annular Fins of Different Cross-sectional Area. Part I. Temperature Distribution and Fin Efficiency", International Journal of Refrigeration, Vol. 35, pp. 365-376, (2012).
 
[14] Moinuddin, A., Sharqawy, M. H., and Zubair, S. M., "Heat and Mass Transfer from Annular Fins of Different Cross-sectional Area. Part II. Optimal Dimensions of Fins", International Journal of Refrigeration, Vol. 35, pp. 377-385, (2012).
 
[15] Nabovati, B., Yaghoubi, M., and Avara, A., "Experimental Study of Free Convection Heat Transfer and Condensation of Vapor of Humid Air over an Inclined Cold Tube", Heat Transfer-Asian Research, Vol. 41, No. 7, pp. 565-579, (2012).
 
[16] Yaghoubi, M., and Mahdavi, M., "An Investigation of Natural Convection Heat Transfer from a Horizontal Cooled Finned Tube", Experimental Heat Transfer: A Journal of Thermal Energy Generation, Transport, Storage and Conversion, Vol. 26, No. 4, pp. 343-359, (2013).
Volume 15, Issue 2 - Serial Number 31
Fluid Mechanics and Heat Transfer
Summer 2013
Pages 62-77

  • Receive Date 23 August 2013